Briefly about EN 90

The FR90 is a advanced fire protection system with high thermal insulation, adapted for both indoor and outdoor use. Med fire class up to EI120, flexible filling options and high sound insulation (up to 47 dB) it is an ideal solution for buildings where fire protection, energy efficiency and sound comfort are crucial. The system offers easy installation and prefabrication, as well as the possibility to integrate security and ventilation functions.
Technical specification
  • Glass
    2 glass, 3 glass, single glass
  • Seasonal
    Summer, Spring/Autumn
  • Leaf depth
    90mm
  • Glazing interval
    20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69
  • Profile width
    90mm
  • Material
    Aluminium
  • Fire class
    EI120, EI30, EI60, EI90
  • Airtightness
    Class 4
  • Watertightness
    Class 4A
  • Wind load
    Class C1

The FR90 is a fire protection system with thermal insulation for both indoor and outdoor installations. The system offers EI30, EI60, EI90 and EI120 fire ratings for walls and EI30, EI60 and EI90 for doors.

System characteristics:

  • Installation: Indoor and outdoor
  • Profile construction:
    • For EI30: Centre chamber filled with gypsum-based filler elements
    • For EI60 and above: All chambers filled with plaster
  • Installation depth: 90 mm, compatible with The STAR system
  • Filling options:
    • Triple glazing (20-69 mm)
    • Panel folding (60 mm):
      • Mineral wool-filled panels (Uᵖ = 0.57 W/m²K)
      • Gypsum-filled panels
  • Types of construction: Single and double doors, fixed glazing
  • Maximum dimensions:
    • Solid walls (single glazing): 6000 × 3000 mm
    • Single-leaf doors: 1650 × 2870 mm
    • Double-leaf doors: 3170 × 2870 mm
  • Locks and fittings:
    • Single and multi-point locks, electric strikes, panic exit devices
    • Cover plate hinge, roller hinge, Inox hinge
  • Other functions:
    • Options with and without threshold
    • Door kick protection (high plinth)
    • Possibility to install ventilation grille
    • Optimised profiles for easier manufacturing
    • Quick and easy prefabrication
    • Acoustics: Sound insulation 39-47 dB for EI30 and EI60 rated double doors