Briefly about Sapa Door EI60 with flue gas density SA/S200

The doors and door sections can be glazed, infilled, combined glazing and infill, with or without glazing bars. The doors can be fitted with door leaf profiles for modular profile locks or narrow profile locks and can be equipped with door closers, automatic door openers, electric strikes, drop locks, panic hardware and anti-crushing devices. The doors can also be made in "Plus" design for even better weather performance.
Technical specification
  • Glass
    2 glass, 3 glass
  • Leaf depth
    86 mm
  • Glazing interval
    23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49
  • Profile width
    67-128 mm
  • Material
    Aluminium
  • Safety class
    RC2, RC3
  • Fire class
    EI60
  • Airtightness
    Class 2
  • Watertightness
    Class 4A

Exterior doors/door sections without smoke gas tightness.
Please note the dimensional limitations depending on the design.

Single door: Max recommended door leaf size W=1350* and H=2930 mm (*for widths up to 1620 mm, contact Architectural Support for advice).

Single door Plus (Airtightness class 2 and Watertightness class 4A): Max door leaf size W=1350 and H=2500 mm.

Pair door: Max recommended total door leaf size W=2613** and H=2930 mm (**for width up to 2900 mm, contact Architect Support for advice). Max door leaf width active W=1350 mm and passive door leaf W=1280 mm. Min door leaf width: 358 mm.

Pair door Plus (Airtightness class 2 and Watertightness class 4A): Max total door leaf size W=2613 and H=2500 mm. Max door leaf width active door leaf B=1350 mm and passive door leaf B=1280 mm. Min door leaf width: 358 mm.

Door sections with single or double doors (inward or outward opening) can be made in width W=3576 mm and height up to H=3576 mm, according to the dimensions above for door leaves.

External doors/door sections with smoke gas tightness Sa/S200.
Please note the dimensional limitations depending on the design.

Single door: Max door leaf size B=1350 and H (Sa)=2930 mm/ H (S200)=2250 mm.

Pair door: Max door leaf size overall W=2625 and H (Sa)=2930 mm/ H (S200)=2250 mm. Max door leaf width active or passive door leaf: W=1321 mm. Min door leaf width: W=358 mm

Door section with single door: Party dimension up to W=2694 and H=3140 mm with single door dimensions as above.

Door section with pair door: Pair dimension up to W=3491 and H=3140 mm with pair door dimensions as above.

Thresholds. The doors can be fitted with or without a threshold in several different designs. See Threshold options.

Sound reduction. Sound reduction. If sound reduction is required, there are variants of laminated sound reduction glass among the approved glasses.

Glass and fillings. Fire structures shall always be constructed with fire glazing or infills approved in the building system. The fire glazing can be combined with burglar- and sound-resistant glass. Also with 2- or 3-glass for low U-values. Max nominal glass thickness 49 mm.

Clamp protection. The doors can be equipped with Athmer Fingerschutz pinch protection on the hinge side and opposite hinge side. It is a mechanical finger guard that is mounted on the rear edge of the door with a strong fabric that is rolled out/in an aluminium profile under constant spring tension.

Protection and security customisation. The doors can be equipped with anti-burglary protection and several different variants of reinforcement profiles and variants with protection plates.

Other. Please note that the maximum dimensions are conditional on total weight, area, opening frequency, etc. Architectural support for more information.